Other Product Offerings
Magnetic contactors are standard in all duct heaters. They are used for primary or back-up control. UL approved for 250,000 cycle operation.
Magnetic contactors are standard in all duct heaters. They are used for primary or back-up control. UL approved for 250,000 cycle operation.
Recommended where noise levels are of concern. Contacts are made and broken between two pools of mercury, separated by a ceramic insulator. Design ensures clean snap action, no chatter and little contact arcing. Position sensitive. Must specify horizontal or vertical air flow. Can be used to de-energize or disconnect the circuit. UL listed for 250,000 cycle operation.
Provides electronic sequencing control of an electric duct heater up to 12 steps. When interruption of power occurs all the stages will recycle to off then and upon the restoring of power, re-energize the switches in a stepping sequence. Commonly used with a 2–10 vDC from a stand alone T-stat, 2-10 vDC from a DDC building automation system and 4-20 ma from a building automation system; check with the factory for availability.
Prevents heater from being energized when the fan is not on. UL Required. Non adjustable airflow switch (shown) requires a minimum of .07”WC pressure. Adjustable airflow switch available with rating of .05” ± .02” WC to 12”WC.
3-Position fuse block
UL standards and NEC code required for heaters drawing more than 48 AMPS. Accessory fusing is available on heaters drawing less than 48 AMPS when requested
Utilized when control voltage differs from line voltage. Primary over current protection. Class 1 units must have primary side protection by fusing. Class 2 units have internal protection and do not require additional fusing unless specified
High voltage terminal blocks are sized for copper conductors only. Sized to accept up to 500 MCM line feeder per pole. Low voltage control circuit terminal boards are included for ease of field connection.
High voltage terminal blocks are sized for copper conductors only. Sized to accept parallel feeders up to 500 MCM each per pole. Low voltage control circuit terminal boards are included for ease of field connection.
Relays provide a time delay of 30 to 60 seconds when energizing or de-energizing the circuit controlled. Standard control voltages of 24 through 277.
Side panel installation for indicating the following heater conditions: heater energized, step energized and air flow switch open. Pilot light control voltages must be 24 or 120 volts.
Provide an interlock when basic control system is pneumatic. Wired to close on pressure rise. Not factory set. Will require field adjustments to specific job requirements.
Solid state relays (SSRs) provide the finest in electric duct heater control. 100% Solid state stepless modulation. Noiseless. Power and heat output precision. Not available on DHB & DB series or bottom mount heaters.
Available unfused door interlocking disconnect switch (max. 384 AMPS).