The following diagram illustrates how to solve for watts, ohms, volts, or amps using Ohm's Law. Click to enlarge.
Fill in any two values to determine the other two:
Ohm's Law Calculator
Temperature Conversion Calculator
°F = (9/5) × °C + 32
°C = (°F - 32) × (5/9)
Length Conversion Tool
Enter a value and select units to convert between
Power//Flow Rate//Temp Calculator
Calculate the electrical power, flow rate or temperature requirement as follows:
SCFM = airflow in standard cubic feet per minute
ΔT = temperature rise in F° from the inlet to the exhaust
Watts = SCFM x ΔT/3
Fill in two values to determine the third.
Three Phase Unit Calculator
Three Phase Unit
Line Current = Wattage / (Voltage * √3)
Belly Bands can be modified to meet the demands of virtually any special application.
| Voltage Rating | Up to 600V |
|---|---|
| Max surface temperature | 150°C (300°F) |
| Max watt density | 0.75W/cm2 (4.5/in2) of circumference |
| Minimum diameter | 150mm (6 Inch) |
| Width | 19mm (3/4 Inch) |
| Sheath Material | 304 Stainless Steel |
| Clamping Style | Quick Release Clamp, 301 SS Strap with 401 SS Hex Screw Head |
| Termination |
Single Pass: Leads on each side of the gap, exiting on the thickness. Double Pass & Narrow Double Pass: Both leads at one side of the gap, exiting on the thickness. |
| Leads | PVC Insulation, 18 GA, 600V, 105°C |
| Ground Wire | Optional, welded to strap. |